Time And Tianhe
There are no products in your shopping cart, go and choose a product!
搜索
Search
inquiry
关闭
>
>
Easydiagnosis dry blood gas analyzer (portable)
1/1
Number of views:
1000

Easydiagnosis dry blood gas analyzer (portable)

Registered member contact customer service Click to Login
Retail price:
9176.0
$
Market price:
14800.0
$
Number:
ST2000
Quantity
-
+
Stock:
0
Login to download
catalogue
Temporarily out of stock
1
COMPLEMENTARY GOODS:
 Werfen blood gas analyzer
Werfen blood gas analyzer
Market price: Available for inquiry
Werfen blood gas analyzer
11137.50
11137.50
Product description
parameter

After 20 years of technical precipitation, the performance is comparable to that of redu and Johnson & Johnson;
Portable dry chemical blood gas analyzer, without reagent, gas cylinder, pump and pump pipe, and maintenance by special personnel;
The software does not need to be upgraded regularly, and the system is stable and easy to use;
The built-in battery of the equipment can be used either in fixed operation or in departments, ambulances or outdoors anytime and anywhere, and the detection of ambulances will not be affected;
The closed blood sample injection system of the instrument protects the medical staff from pollution;
Interactive touch screen operation, only three steps to complete the detection, no special training, no special operation;
It only takes 60 seconds to report the results;
The reagent card is calculated by one person, without any additional consumption, and the detection cost is low;
The reagent card is valid for 6 months without refrigeration, which is convenient for storage and transportation and reduces the transportation cost;
Different reagent cards can be replaced at any time for different test items, and the cost is easy to control;
Calibrate first and then inject blood sample to avoid sample waste;
The product has strong applicability and can meet the needs of different detection quantities;

We could not find any corresponding parameters, please add them to the properties table

Reagent card test parameters
Reagent card type
Test parameters
Calculation parameters
CC
pH, pCO2, pO2, Na+, K+, iCa, Hct
HCO3-, TCO2, BEb, BEecf, O2Sat, tHb, iCa(N)
Irma Kit
size
two point six × one point three × 0.6 inches,
sixty-six × thirty-three × 15.24 mm
weight
5 - 7 oz., 15 - 21 g
Sample volume
0.125 - 3.0 mL
4.3 detailed introduction of instrument
Technical parameters of ST2000 blood gas analyzer
Detectable parameters
parameter
Company
Detection range
PH
pH units
6.000~8.000
PCO2
mmHg
4~200
PO2
mmHg
20~700
Hct
%
10~80
Na+
mmol/L
80~200
K+
mmol/L
85~180
iCa
mmol/L
0.25~4.0
Analysis time
60 seconds
working temperature 
Instrument / reagent: 12~30 ℃;
Storage temperature
Instrument: 0~50 ℃
Reagent: 15~30 ℃ (CR 2~8 ℃)
Operating humidity
0~80% (non condensing)
sample size
one hundred and twenty-five μ L (capillary); two hundred μ L (syringe)
Volume and weight
Reagent card / temperature card: 66 × thirty-three × 15.24; 15~21g;
printer
Thermal printer
System docking
Seamless connection with hospital lis/his system, real-time data sharing;
Irma base
size
ten point three × nine × 2.7 inches
two hundred and sixty-one point six × two hundred and twenty-eight point six × 68.6 mm
Weight (excluding IRMA plate)
53 oz, 3.5 lbs, 1500 g
Power Supply
AC adapter or battery
DC input
12 V DC, 5.0 Amps
Interface
one × USB 2.0
Bluetooth
V2.1+ EDR Level 2
Security
Secure simple pairing (SSP);
128 bit encryption
Compliance with FCC
Contains FCC id: qoqwt12
Including ic: 5123a-bgtwt12a
Irma base battery
pattern
Rrc2057 lithium ion
Charging time
< 7 hours
Battery capacity
7.5 V, 6400 mA H
Rechargeable battery, which can detect 80 samples after being fully charged;
compliance
UL2054, IEC62133, UN38.3
Irma plate
size
nine point nine × zero point seven × 5.8 inches
two hundred and fifty-one point five × eighteen × 147 mm
weight
20 oz. 570 g
DC input (from base)
5 VDC, 2 Amps
pattern
Nvidia, Shield K1 Tablet
display
8 inch, 1920 × 1200 touch HD display
wireless
802.11n 2x2 MIMO 2.4 GHz and 5GHz Wi-Fi,
Bluetooth 4.0 LE,GPS / GLONASS
security
WPA/WPA2
Battery
3.8 V, 5100 mAH
Compliance with FCC
FCC ID: VOB-P1761WX (P/N 940-81761-2500-xxx WIFI),  VOB-P1761WX.  CONTAINS FCC ID: VOB-E1729
(P/N 940-81761-2500-xxx LTE)
Irma ac/dc converter
pattern
SLPower Electronics, ME60A1203F01
size
four point two × two point six × 1.3 inches
one hundred and six point seven × sixty-six × 33 mm
weight
14.3 oz.
400 g
input
100 - 240 VAC, 1.5 Amps, 50 - 60 Hz
output
12 VDC, 5 Amps
compliance
EMC UL/EN/IEC60601-1-2, 4th edition, EN55011/CISPR11, FCC Part 15.109 Class B Conducted &amp; Radiated Emissions Compliance Safety IEC 60601-1(ed.3) for Safety
CB Scheme
E302267-D1010-1-CB issued on 2015-10-02
Energy compliance
DoE Efciency Level VI
power cord
IEC 320 C13
4.4 key clinical application departments
Operating room, anesthesiology department, ICU, cardiothoracic surgery department, respiratory department, neonatology department, emergency department, etc.

Related documents

There is currently no content to display
Please add data record on website background.
There is currently no content to display
Please add data record on website background.
NEW ARRIVALS:
High-frequency electrosurgical unit
High-frequency electrosurgical unit
Market price: Available for inquiry
Negative pressure suction
Negative pressure suction
Market price: Available for inquiry

shopping cart

noGoods
No goods

What are you looking for:

Copyright © 2010-2021 Qisheng ( shanghai ) Medical equipment Co.,Ltd  ICP:2551450111