SuperMark 1.5T ANKE Superconducting magnetic resonance imaging system MRI
1/1
Number of views:
1000

SuperMark 1.5T ANKE Superconducting magnetic resonance imaging system MRI

Registered member contact customer service Click to Login
Retail price:
0.0
$
Market price:
0.0
$
Category:
Imagery
MRI
Number:
SuperMark 1.5T
Quantity
-
+
Stock:
0
Login to download
catalogue
Temporarily out of stock
1
COMPLEMENTARY GOODS:
 BTl-030 MRI
BTl-030 MRI
Market price: Available for inquiry
 BTI-035 MRI
BTI-035 MRI
Market price: Available for inquiry
Product description
parameter


Introduction of SuperMark 1.5T
SuperMark 1.5T is a new generation superconducting MRI system designed focused on user concerns, based 
on over 30 years of experience in research and development. This system is equipped with a new generation 
of hardware and software platforms to benefit users a lot and provide patients with more comfortable 
experiences. It features new user-friendly design, faster imaging speed, higher image quality and high work 
efficiency.
SuperMark 1.5T provides not only conventional pulse sequences and basic clinical applications, but also 
advanced functional applications. It adopts brand new APEX operating system which ensures easy operation 
and fast diagnosis.
◆ Short bore magnet with zero liquid helium “0” boil-off technology;
◆ Powerful and high linearity gradient system, Soft-sound to decreases the noise of scanning;
◆ High efficiency RF system combined with Dual-engine parallel acquisition technology;
◆ ART platform provides easy handling and good image quality in combination scanning;
◆ AI combined platform provide more comfortable operating experience;
◆ Complete clinical application package to meet all your clinical needs.
Technical advantages
Magnet system
Traditional long magnet has a very long aperture, which seriously affects the comfort of patient examination.
SuperMark 1.5T system is equipped with an optimally designed short bore superconducting magnet, the 
length of magnet is only 157cm, it can greatly improve the patient examination experience.
Homogeneity of the main magnetic field is the basis of MR imaging. A good magnetic field homogeneity
helps to realize a wide range of abdominal scanning and off-center joints scanning. In particular, fat 
suppression imaging has a high requirement for the homogeneity of magnetic field.
ANKE provides unique ADS (Automatic 3D dynamic shimming) technology, which automatically performs 3D 
dynamic shimming according to the tissue and structural characteristics of different parts of human body 
during scanning. This can greatly reduce problems such as image distortion and failure of fat suppression 
caused by local magnetic field inhomogeneities.
Short bore magnet
ADS technology
Ultra-low liquid helium capacity design, only 700L (100% fill in) liquid helium is required to ensure a stable 
running of the magnet. 
Equipped with 4K cold head and liquid helium “0” boil-off technology, which ensure stably running for more 
than 5 years without liquid helium fill in.
Liquid helium “0” boil-offShenzhen Anke High-tech Co., Ltd.
www.anke.com 6
With 24-hour unattended function, it can access the cloud server, monitor the magnet status online, and 
receive early warning information in real time to avoid major losses.

Warranty
SuperMark 1.5T supplied by ANKE will be, under normal and proper use and care, free from all defects or 
deficiency in design, material and workmanship for the Warranty Period as specified below:
1) Warranty Period (from acceptance date): 12 months.
2) The warranty shall not extend to:
◆ Any products that are misused or that have malfunction attributable to negligence or accidents.
◆ Any products where ANKE’s original serial number tag or product identification markings have been 
altered or removed.
◆ Any products repaired by anyone unauthorized by ANKE.
The guarantee covers all the materials, main accessories that will be shipped directly from the factory and we 
offer the service technically by the Internet of 7 x 24 hours.
Standard configuration (Simple)4)
1. Main components and accessories
No. Descriptions Quantity
1.1 Main imaging system 1 set
1.2 Magnet system 1 set
1.3 Standard cover 1 set
1.4 Gradient system 1 set
1.5 16ch digital spectrometer system 1 set
1.6 RF transmitting system 1 set
1.7 16ch-ART RF receiving system 1 set
1.8 Patient table and control system 1 set
1.9 Patient communication system 1 set
1.10 Patient supervision TV system (CCTV) 1 set
1.11 Physiological gating system 1 set
1.12 Console system 1 set
1.13 Console table and chair 1 set
1.14 Dedicated isolated regulation power supply 1 set
1.15 Electronic cabinet (With standard PDU inside) 1 set
1.16 1KVA UPS (For console system only) 1 set
1.17 Water cooling system 1 set
1.18 Standard RF shielding cage 1 set
1.19 Accessories 1 set
1.20 Standard software package 1 setShenzhen Anke High-tech Co., Ltd.
23 www.anke.com
2. Standard RF coils
No. Descriptions Quantity
2.1 Transmitting & Receiving integrated body coil 1 set
2.2 Head/Neck coil – 18 1 set
2.3 Spine coil – 18 1 set
2.4 Body coil – 6 1 set
2.5 Large flex coil – 8 1 set
2.6 Small flex coil – 4 1 set
2.7 Knee coil – 8 1 set
2.8 Coil accessories 1 set
2.9 Standard coil cabinet 1 set
4) Standard configuration (Simple) is for reference only, please contact to ANKE for future information.Shenzhen Anke High-tech Co., Ltd.
Address: Block B, LingYa Industrial Zone, Tangtou No.1 Road, Bao'an
District, Shenzhen, 518108, P.R. China
Tel: +86-755-21622518 26688889
Fax: +86-755-26695307 26685908
Email: anke@anke.com 
Website: www.anke.com
Twitter: ANKE (@ankeint)
Facebook: ANKE (@ankemri)
Instagram: ANKE (@ankemarcom)
Linkedin: Shenzhen Anke High-tech Co., Ltd.
Specifications and appearance of the equipment may change without prior notice. ANKE reserves the right of final interpretation.

We could not find any corresponding parameters, please add them to the properties table

Magnet specifications
Magnet type Superconducting
Magnetic field strength 1.5T ± 1%
Magnet length 157cm
Magnet bore diameter 605mm±5mm
Weight (including 100% liquid helium) 3800kg
Liquid helium volume (100% liquid helium) 700L
Liquid refilling interval ≥ 5 years
Magnetic field homogeneity ≤ 0.170ppm @40cm DSV (VRSM)
Safe and reliable
Gradient system
◆ Water-cooled gradient amplifier and coil, ensure the whole system working in maximum performance.
◆ Eddy-“0” technology, through the combination of hardware and software, the eddy current is 
compensated to the maximum extent, ensure excellent imaging quality.
◆ Ultrafast solid-state technology with very low switching losses.
◆ Excellent linearity, easy to achieve a wide range of scanning.
Powerful output
Max. amplitude (single axis) 40mT/m
Max. Effective amplitude 69mT/m
Max. slew rate (single axis) 150T/m/s
Max. Effective slew rate 259T/m/s
Min. rise time 0.27ms
Duty cycle 100%
The technology of maximum gradient amplitude and slew rate to arrive at the same time is provided.
General features
Structurally stable magnet and gradient coil with new design of noise reduction material, these two parts are 
closely connected, and the force is balanced in all directions, which can effectively reduce the vibration in the 
scanning process, thus reducing the noise.
The optimized sequence parameters can effectively avoid the resonance of the gradient coil, on the premise 
of ensuring image quality and scanning time, the noise generated by scanning is greatly reduced.
Soft sound technologyShenzhen 
RF (Radio Frequency) system
◆ High efficiency RF system, equipped with new and unique
technology, reducing electrical noise and increasing signal 
detection.
◆ Real-time RF energy monitoring technology, include shortterm and long-term accumulation monitoring.
◆ The ART (Adaptive and Rapid Total-imaging) platform is 
equipped with an integrated coil, which can easily achieve a 
wide range of body scanning, greatly improving operation 
convenience and scanning efficiency.
Transmit technology
RF amplifier maximum power 20kW
Center frequency 63.86 MHz ± 275 kHz
Transmission bandwidth 550kHz
RF amplifier Cooling type Water cooling
RF receiving Technology
Number of independent channels 16
Receiving bandwidth 2.0MHz
General features
RF (Radio Frequency) coils
Transmitting & Receiving integrated Body Coil for whole-body coverage scan, can be seamlessly connected 
with the phased array coils, greatly improve SNR and uniformity of images.
The ART (Adaptive and Rapid Total-imaging) coils are designed for high image quality in combination with 
easy handling. No-tune high element coils increase SNR and reduce examination times.
Standard coils
Head/Neck coil – 18
Elements 18 elements, 8 for head and 10 for neck
Dimensions (L×W×H) 43cm×33cm×32cm
Weight 5.0kg
Applications • Head imaging
• Neck imaging
• C-spine imaging
• Head & neck MR angiography
• Head & neck combined imaging
• TMJ (temporomandibular joints) imaging
Typically combined with • Spine coil – 18
• Body coil – 6
• Large flex coil – 8
• Small flex coil – 4
Spine coil – 18 Elements 18 elements, 6 rows of 3 elements each
Dimensions (L×W×H) 95cm×46cm×4cm
Weight 15.0kg
Applications • High resolution imaging of the whole spine
• Various applications in combination with 
additional coils
Typically combined with • Head/Neck coil – 18
• Body coil – 6
• Large flex coil – 8
• Small flex coil – 4
Integrated body coil
ART (Adaptive and Rapid Total-imaging) coils
Body coil – 6
Elements 6
Dimensions (L×W×H) 51cm×31cm×2.7cm
Weight 1.7kg
Applications • Thorax imaging
• Abdomen, Pelvis & Hip imaging
• Abdomen MR angiography
Typically combined with • Head/Neck coil – 18
• Spine coil – 18 
• Additional Body coils (optional)
• Large flex coil – 8
• Small flex coil – 4
Large flex coil – 8
Elements 8
Dimensions (L×W×H) 51cm×23cm×2.7cm
Weight 1.4kg
Applications Imaging of large regions, such as medium to 
large shoulder, hip, and knee.
Typically combined with • Head/Neck coil – 18
• Body coil – 6
• Small flex coil – 4
Small flex coil – 4
Elements 4
Dimensions (L×W×H) 36cm×18cm×2.7cm
Weight 0.8kg
Applications Imaging of small regions, such as small to 
medium shoulder, wrist, elbow, and ankle.
Typically combined with • Head/Neck coil – 18
• Body coil – 6
• Large flex coil – 8
Knee coil – 8 Elements 8
Dimensions (L×W×H) 42cm×27cm×27cm
Weight 4.9kg
Applications • High resolution knee imaging
• Lower extremities joint imaging
Comprehensive Applications
Combined with the advanced hardware design, Soft sound technology can be used for whole body scanning
without image quality lose, which will provide a more comfortable scanning experience for patients. All the 
images bellow are collected by soft-sound sequence.
Parallel acquisition is a technology to reduce the time of 
signal acquisition, in SuperMark 1.5T, we supply 2 kind of 
reconstruction method:
◆ SENSE (SENSitivity Encoding) technology based on 
Image domain.
◆ GRAPPA (GeneRalized Auto calibrating Partially 
Parallel Acquisition) technology based one K-space.
Parallel acquisition technology can fully satisfy your daily 
application needs and enhance the work efficiency.
Full soft-sound platform
Dual-engine parallel acquisition technology
With the development of computer technology, Artificial Intelligence (AI) technology has been more and 
more widely used in some high-tech fields. Especially in the field of medical imaging, AI technology is also 
increasingly used in process optimization, image processing, and auxiliary diagnosis, etc. which can greatly 
improve work efficiency and reduce the workload of medical workers. As one of the top leading high-tech 
medical imaging manufacturers, ANKE has always been committed to the research on the application of AI
technology in MRI.
◆ AI-Auto Localization technology
AI-Auto Localization technology uses AI to 
separate the tissues of the vertebral body, 
then find the corresponding intervertebral 
disc based on the vertebral body and place the 
cross-sectional positioning line parallel to the 
long axis of the intervertebral disc and 
perpendicular to the sagittal plane of the 
spine. This can greatly reduce the complexity 
of the operation, also, it can save time and 
avoid position and angle errors caused by 
manual operation.
◆ AI-Image Enhancement
 
Combined with fast scanning sequence, AI image enhancement technology can greatly shorten patient 
scanning time, improve patient comfort, and increase the number of patient scans in the hospital every day.
AI technology for MRI imaging
◆ AI motion correction
 
AI motion correction can reduce the image artifact by different data acquisition and reconstruction methods.
◆ AI image stitching
AI image stitching is based on AI recognition technology, which can automatically combine images without 
manual recognition and adjustment. This technology can automatically output whole-spine images, wholebody images, and whole-body DWI (PET-Like) images, etc.
TOF (Time-of-Flight) 2D/3D based on the enhancement effect of blood flow, and is mainly used for the 
examination of cerebral blood vessels, neck blood vessels, and lower limb blood vessels. 
CEMRA (Contrast Enhanced MR Angiography) 2D/3D for single step, dynamic, peripheral with the shortest 
TR and TE. The strong gradients make it possible to separate the arterial phase from the venous phase.
PCMRA (Phase Contrast MR Angiography) can be used for venous or sinus scanning, cerebrospinal fluid or 
blood flow, flow, flow direction analysis, etc.
ASL-MRA (Arterial Spin Labeling MR angiography) is a non-contrast MRA imaging function based on SSFP 
sequence. This function can be used to produce images of portal veins, renal arteries, and upper and lower 
extremity arteries.
MTC (Magnetization Transfer Contrast) technology and TONE (Tilted Optimized Non-saturation Excitation)
pulse to improved Contrast to Noise Ratio of images.
Multiple angiography imaging
DWI (Diffusion Weighted Imaging) is to show Brownian motion of water molecules by applying diffusion 
sensitive gradient on the basis of EPI (Echo Plane Imaging) sequence.
In SuperMark 1.5T system, we supply EPI (Echo Planar Imaging) with Single Shot and Multi Shot technology 
for high-definition diffusion weighted imaging. In one scanning, you can obtain 4 images of DWI: DWI images 
with high b-value, DWI images with 0 b-value, ADC-map, eADC-map.
 
DWI is a necessary function for the examination cerebral infarction, brain tumor, malignant lesions (body)
and bone tumor, etc.
DTI (Diffusion Tensor Imaging)1)
is a more accurate description of the anisotropy of water molecular motion,
with multiple diffusion-weightings and up to 256 directions for generating data sets for diffusion tensor 
imaging.
 
1) Optional functions. To obtain more accurate image information, the Diffusion tensor imaging (DTI) analysis software (optional) and 
other accessories are required.
High-definition diffusion imaging
SWI (Susceptibility weighted imaging) is 
using the magnetic sensitive 
characteristics of deoxyhemoglobin, to get 
the image of veins, bleeding and nonheme iron deposits.
APT (Amide Proton Transfer) imaging is a noninvasive imaging technique based on chemical exchange 
saturation transfer technology.
APT is a reflection of protein distribution in MRI which can be used to assess protein expression of tumor, 
stroke and other brain diseases, and provides important information for diagnosis and treatment.
Susceptibility weighted imaging (SWI)
Amide Proton Transfer Imaging
PWI (Perfusion Weighted Imaging)3)
is observing the changes in cerebral 
hemodynamics by EPI technology.
Inline Perfusion helps to streamline 
the clinical workflow by automating 
post-processing perfusion data during 
data acquisition. Neuro Perfusion 
measures perfusion deficits and assist 
in the diagnosis and grading of e.g. 
vascular deficiencies and brain 
tumors.
DCE (Dynamic Contrast Enhanced) is a noninvasive imaging method to detect and evaluate the vascular 
status of tumors or other tissues by injecting contrast agents.
 
FAST 3D – DCE (Dynamic Contrast Enhancement) imaging with full abdominal coverage scan, can easily to 
capture the process of lesion signal enhancement, help you analyze the lesion more accurately.
2) Optional functions. To obtain more accurate image information, the MRI perfusion analysis software (optional) and other 
accessories are required.
Perfusion weighted imaging2)
Dynamic contrast enhancement imaging
SuperMark 1.5T provide multiple precise fat and water imaging technologies.
STIR (Short Time Inversion Recovery) 
FS (Fat Saturation) technology based on frequency selective RF pulses with 2 selectable modes: weak, strong
SPAIR (Spectral Adiabatic Inversion Recovery), combined with frequency selective inversion pulse to obtain 
a high-quality fat suppression body imaging
WE (Water Excitation) technology, can show the cartilage structure clearly
DIXON (Water and Fat Separation) technology.
Multiple fat and water imaging
Installation
380VAC ± 10%, 50/60 Hz, ±1Hz, Connection value 80 kVA
Scanning room 6.00m x 5.00m
Operation room 3.00m x 3.00m
Equipment room 3.00m x 4.00m
3) The final implementation plan depends on the condition of customer’s site, for more information, please refer to the site planning 
manual.
Scanning room Operation room
Equipment room
Dressing 
room
Waiting area
Power Requirements
Recommended dimension3) 

Related documents

There is currently no content to display
Please add data record on website background.
There is currently no content to display
Please add data record on website background.
NEW ARRIVALS:
High-frequency electrosurgical unit
High-frequency electrosurgical unit
Market price: Available for inquiry
Negative pressure suction
Negative pressure suction
Market price: Available for inquiry

shopping cart

noGoods
No goods

What are you looking for:

Copyright © 2010-2021 Qisheng ( shanghai ) Medical equipment Co.,Ltd  ICP:2551450111