Time And Tianhe
There are no products in your shopping cart, go and choose a product!
搜索
Search
inquiry
关闭
>
>
Jinhao ambulatory ECG recorder
1/1
Number of views:
1000

Jinhao ambulatory ECG recorder

Registered member contact customer service Click to Login
Retail price:
1192.0
$
Market price:
1788.0
$
Number:
EXC-60A
Quantity
-
+
Stock:
0
Login to download
catalogue
Temporarily out of stock
1
COMPLEMENTARY GOODS:
 Portable monitor ECG6
Portable monitor ECG6
Market price: Available for inquiry
 Kangtai electrocardiograph ECG-1200G
Kangtai electrocardiograph ECG-1200G
Market price: Available for inquiry
 photoelectric ambulatory ECG workstation rac-2512
photoelectric ambulatory ECG workstation rac-2512
Market price: Available for inquiry
Product description
parameter

Dynamic monitoring of ECG. 1. detection of occult arrhythmias: transient arrhythmias that begin to appear under specific circumstances are easy to be missed by routine ECG, while DCG can capture transient abnormal ECG changes to understand the origin of arrhythmia The duration, frequency, occurrence and termination rules can be analyzed synchronously with clinical symptoms and daily activities. 2. monitoring tachyarrhythmia: to further understand its occurrence and termination Whether there is SSS syndrome or preexcitation syndrome (especially intermittent) and its classification. 3. observe bradyarrhythmia: understand its main manifestations and whether there is sinus node dysfunction. For fast slow syndrome, DCG observation can help to select antiarrhythmic drugs, adjust dosage or consider other treatment methods, so as to provide objective basis for pacemaker installation and type selection. 4. assist in judging the clinical significance of different types of ectopic rhythm or conduction block: monitor the frequency and severity of ectopic rhythm or conduction block through DCG, and determine the corresponding relationship with life or activity, and determine the treatment policy. 5. evaluate the efficacy of antiarrhythmic drugs: DCG is a reliable clinical index for the study and evaluation of antiarrhythmic drugs. 6. find out the potential risk factors of sudden death. The most common cause of sudden cardiac death is ventricular tachycardia or ventricular fibrillation. Before the occurrence of sudden cardiac death, there are often ventricular arrhythmias with unstable cardiac electrical activity, which can only be easily found by DCG. For patients with mitral valve prolapse, hypertrophic or dilated cardiomyopathy and Q-T prolongation syndrome who may have sudden death, DCG can find out the risk factors of sudden death timely and comprehensively, which is helpful to take effective treatment measures in time. 7. assist in judging whether intermittent symptoms such as chest tightness, palpitation, dizziness, amaurosis or syncope are cardiogenic. 8. Continuous monitoring of 12 lead ECG by DCG has a high detection rate of myocardial ischemia, and can also be used for location diagnosis, especially for myocardial ischemia with atypical symptoms. Myocardial infarction or asymptomatic myocardial ischemia has irreplaceable clinical value. The activity correlation analysis of ST-T changes and time synchronization is helpful to judge the type of myocardial ischemia and select drugs. In addition, it can detect the type and frequency of arrhythmias associated with myocardial ischemia, and predict the possibility of sudden cardiac death, so as to take preventive measures as soon as possible.

We could not find any corresponding parameters, please add them to the properties table

1: Technical parameters
1. Recording mode: 12 lead synchronous continuous
2. Number of leads: 12
3. Recording time: ≥ 24 hours
4. Power supply: one No. 5 battery
5. Amplifier frequency response range: 0.5-100hz   
6. Input impedance ≥ 2.5m Ω.
7. Loop current ≤ 0.1 μ A。
8. Sensitivity control: 10mm/mv, error ± 5%.   
9. Noise level ≤ 15 μ Vp-p。
10. Common mode rejection ratio: ≥ 60dB.
11. amplitude frequency characteristic: Based on 10Hz, it should be (0.5 ~ 75Hz) + 0.4db-3.0db.
12. Low frequency characteristics: the time constant shall be ≥ 3.2s.
13. Baseline drift: ≤ 1mm.
14. Temperature drift: within the temperature range of 5 ℃ ~ 40 ℃, the average baseline drift is ≤ 0.5mm/ ℃.
2: Functional features
1. video ambulatory ECG (the use of video ambulatory ECG can completely eliminate the problems that are difficult to distinguish in the management of duplicate cases)
2. the words and tables on the software are fully colored and can be customized
3    the exquisite and compact recording box uses U-disk media to store data, making it have super anti-interference and anti-seismic capabilities
4   high fidelity ECG sampling and data recording to provide real data for diagnosis
5    high quality, high shielding anti-interference lead wire, made of bulletproof material, durable
6   recording box weight: 35g size: 68*48*16 (unit: mm)
7. The software receives data at a high speed for only 0.5 seconds. Software automatic analysis is fast and takes only 1-3 seconds
8. switching leads: 12 lead single leads can be switched to each other
9. Dynamic and intelligent template classification and multi template leading function make ECG analysis faster
10. Template graphics display can display 100 at a time and zoom in in in real time
11. 12 lead and single lead can be switched to each other at any time
12. It has perfect analysis functions, such as ST-T analysis, heart rate variability analysis, QT dispersion analysis, total myocardial ischemia load analysis, pacing analysis, superposition analysis, etc.
13. Report printing paper is optional
14. Software language: Chinese and English can be switched directly
15. Software analysis includes interval matching and amplitude matching

Related documents

There is currently no content to display
Please add data record on website background.
There is currently no content to display
Please add data record on website background.
NEW ARRIVALS:
High-frequency electrosurgical unit
High-frequency electrosurgical unit
Market price: Available for inquiry
Negative pressure suction
Negative pressure suction
Market price: Available for inquiry

shopping cart

noGoods
No goods

What are you looking for:

Copyright © 2010-2021 Qisheng ( shanghai ) Medical equipment Co.,Ltd  ICP:2551450111